TransducerandDSMsettings
SelectingtheDSMandtransducersettings
Fromthemainshnderscreen:
1.PresstheMENUbutton.
2.SelectFishnderSetupfromthelistofoptions.
3.Selectfromthelistofmenuoptions:
•TransducerSettings
•DSMSettings
FishnderDSMSetupMenuOptions
Nearbyvesselsequippedwithashnder,orcertainphysicalconditions(likehardseabeds),canaffecttheDSM.Itssetupmenusenable
youtochangesettingstoallowforthis.
MenuItemDescriptionOptions
DSMResetRestoreallsettingsontheDSMtofactorydefault.When
performingaDSMReset,itisnormaltobrieylooseconnection
withtheDSM.
Yes,No
TripCounterResetResetstheTripCounteroftheDSM.
Yes,No
SONARInterferenceRejectionRemovesspikescausedbyothershnder-equippedvessels.
Auto,Low,Medium,High
2ndEchoInterferenceRejection
Adjuststhepingrateinsmallincrements,accordingtothe2nd
echolevel.Thisresultsinbettersensitivityoftheimage.
Off,Low,High
PingRateLimit(persecond)Providesaspeedlimiter;itisusefultoadjustthepingratetosuit
localconditions.Forexample,thepingratemaybetoofastwhen
thereisahardbottominshallowwater.Thissettingrevertsto26
pingspersecondwhentheDSMunitispoweredoff.
5to30pingspersecond(30default)
PingEnableThesonarpingisnormallyenabled.Itcanbedisabled.Thisis
usefulwhenotherequipmentisbeingtested,orifsomeoneis
divingbeneaththeboat.ThissettingrevertstoEnabledwhen
theDSMunitispoweredoff.
Disabled,Enabled