6.AttheendoftheoutwardlegpressTripagain.
ThetextRETURNwillashatthetopofthepageandthe
displayeddistancefreezes.
Note:Thedisplayeddistancevaluemaynotbethesameasthe
measureddistance,duetoerrorsintroducedbytidalow.
7.Turnyourvesselround,startthereturnlegandasyoudo
so,presstheTripbuttonsoRETURNstopsashingandthe
displayedvalueincrements.
8.Attheendofthereturnleg,presstheTripbutton.
Atthispoint:
•ThetextSTART2alternatingwiththenewcalibrationfactoris
displayedatthetopofthepage.
•Thedisplayeddistancefreezes
Note:Thedisplayeddistanceshouldbeveryclosetotheactual
(measured)distanceofthecalibrationrun.
9.Ifyouaresatisedwiththeresultsoftherstcalibrationrun,
presstheSpeedandTripbuttonssimultaneouslytosavethe
newcalibrationfactorandexitspeedcalibration.
10.Ifyouwanttocarryoutasecondcalibrationrun,presstheTrip
button.
11.Followsteps5to7aboveagaintocompleteasecondcalibration
run.
12.AttheendofthereturnlegpresstheTripbutton
Atthispoint:
•ThetextENDalternatingwiththenewcalibrationfactoris
displayedatthetopofthepage.
•Thedisplayeddistancefreezes
13.Toexitthespeedcalibrationrunatanytime,pressandholdthe
SpeedandTripbuttonssimultaneouslyfor4seconds.
Checkingi50Tridatasoftwareversionandstatus
Speed
Depth
10
15
20
25
30
35
40
45
50
55
60
5
4
+
Speed
D12 4 6 1 -1
Duringnormaloperation:
1.PressandholdtheDepthandSpeedbuttonssimultaneously
for4seconds:
Thesoftwareversionisdisplayed.
2.PresstheSpeedbuttontodisplaytheinstrumentstatus.
Master(transducerconnected)orRepeater(Notransducer
connected).
3.T ochangethedepthstatus:
i.PresstheTripandResetbuttonssimultaneouslytoenter
adjustmode.
Thestatusasheswheninadjustmode.
ii.PresseitherTriporResettoswitchthestatusbetween
MasterorRepeater.
4.PresstheSpeedbuttonagaintobeginspeedruncalibration.
5.T oexittheIntermediatecalibrationsettingsatanytime,press
andholdtheDepthandSpeedbuttonssimultaneouslyfor4
seconds:
Performingspeedruncalibration–i50Tridata
Thisspeedcalibrationinvolvescarryingoutupto2runsovera
measureddistance,toenableacalibrationfactortobedetermined
andappliedtoyourunit.Eachrunconsistsofanoutwardanda
returnleg,tominimizetheeffectoftidaldriftwhenthecalibration
factorisdetermined.
FromtheIntermediatecalibrationpage:
Note:Thisprocedureisnotrequiredifcurrentspeedissetto
SOG.
1.PresstheSpeedbuttonuntilyoureachtheCalibrationrun
lengthpage.
2.PresstheTripandResetbuttonssimultaneouslytoenteradjust
mode.
Inadjustmodetherunlengthashes.
3.UsetheTriporResetbuttontosettherunlengthtotherequired
value(between0.25and2.50).
4.PresstheTripandResetbuttonssimultaneouslytocommence
thespeedruncalibration
Thecalibrationstatuspageisdisplayed.Thetextatthetopof
thepagealternatesbetweenSTART1andthecalibrationfactor
currentlyapplied.
5.Starttheoutwardlegofthecalibrationrunandasyoupass
thestartpoint,presstheSpeedbutton,sothepageshows
OUTWARDatthetop.Asthecalibrationrunproceeds,the
displayedvaluewillchange.
6.AttheendoftheoutwardlegpressSpeedagain.
ThetextRETURNwillashatthetopofthepageandthe
displayeddistancefreezes.
Note:Thedisplayeddistancevaluemaynotbethesameasthe
measureddistance,duetoerrorsintroducedbytidalow.
7.Turnyourvesselround,startthereturnlegandasyoudoso,
presstheSpeedbuttonsoRETURNstopsashingandthe
displayedvalueincrements.
8.Attheendofthereturnleg,presstheSpeedbutton.
Atthispoint:
Gettingstarted
35
Kommentare zu diesen Handbüchern