9.IftheSOGpageisdisplayedandthetideconditionsareslack,
pressandholdtheResetbuttonfor3secondstoacceptSOG
asthecurrentspeed.
D12 4 4 7-1
Re s e t
10
15
20
25
30
35
40
45
50
55
60
5
3
10.Alternatively,withthecalfactorpagedisplayedusetheTripor
Resetbuttonstosetthecalfactortoyourvessel'sestimated
currentspeed.
11.PresstheSpeedbuttontodisplaythetemperatureunitspage.
D12 4 4 8-1
Spe e d
12.PresstheSpeedbuttontodisplaythetemperaturecalibration
page.
D12 4 4 9-1
Spe e d
13.UsetheTriporResetbuttonstosettheunittoshowthecurrent
watertemperature.
14.PresstheSpeedbuttontodisplaytheTimerbuzzerpage.
D12 4 5 0-1
Spe e d
15.UsetheTriporResetbuttonstoswitchthecount-upandrace
starttimerbuzzersonandoff.
16.Toexittheusercalibrationpagesatanytime,pressandholdthe
DepthandSpeedbuttonssimultaneouslyfor2seconds.
Intermediatecalibration
Intermediatecalibrationallowsyouto:
i50Depthi50Speedi50Tridata
Checkinstrument
softwareversion.
Checkinstrument
softwareversion.
Checkinstrument
softwareversion.
Checkandifnecessary
changetheinstrument
status(eithermasteror
repeater).
Checktheinstrument
status(eithermasteror
repeater).
Checkandifnecessary
changetheinstrument
status(eithermasteror
repeater).
Carryoutacalibration
runoverameasured
distancetoensure
accuratespeed
readings.
Carryoutacalibration
runoverameasured
distancetoensure
accuratespeed
readings.
Checkingi50Depthsoftwareversionandstatus
Depth
Alarm
10
15
20
25
30
35
40
45
50
55
60
5
4
+
Depth
D12 4 5 1-1
Duringnormaloperation:
1.PressandholdtheDepthandAlarmbuttonssimultaneously
for4seconds:
Thesoftwareversionisdisplayed.
2.PresstheDepthbuttontodisplaytheinstrumentstatus.
Master(transducerconnected)orRepeater(Notransducer
connected).
3.T ochangethestatus:
i.PresstheOffsetandResetbuttonssimultaneouslytoenter
adjustmode.
Thestatusasheswheninadjustmode.
ii.PresseitherOffsetorResettoswitchthestatusbetween
MasterorRepeater.
4.T oexittheIntermediatecalibrationsettingsatanytime,press
andholdtheDepthandAlarmbuttonssimultaneouslyfor4
seconds.
Checkingi50Speedsoftwareversionandstatus
Speed
Trip
10
15
20
25
30
35
40
45
50
55
60
5
4
+
Speed
D12 4 5 2-1
Duringnormaloperation:
1.PressandholdtheSpeedandTripbuttonssimultaneouslyfor
4seconds:
Thesoftwareversionisdisplayed.
2.PresstheSpeedbuttontodisplaytheinstrumentstatus.
Master(transducerconnected)orRepeater(Notransducer
connected).
3.PresstheSpeedbuttonagaintobeginspeedruncalibration.
4.T oexittheIntermediatecalibrationsettingsatanytime,press
andholdtheSpeedandTripbuttonssimultaneouslyfor4
seconds.
Performingspeedruncalibrationi50Speed
Thisspeedcalibrationinvolvescarryingoutupto2runsovera
measureddistance,toenableacalibrationfactortobedetermined
andappliedtoyourunit.Eachrunconsistsofanoutwardanda
returnleg,tominimizetheeffectoftidaldriftwhenthecalibration
factorisdetermined.
FromtheIntermediatecalibrationpage:
Note:Thisprocedureisnotrequiredifcurrentspeedissetto
SOG.
1.PresstheSpeedbuttonuntilyoureachtheCalibrationrun
lengthpage.
D12 4 5 3-1
Spe e d
2.PresstheTimerandResetbuttonssimultaneouslytoenter
adjustmode.
D12 4 5 4-1
Re s e tTim e r
+
Inadjustmodetherunlengthashes.
3.UsetheTimerorResetbuttontosettherunlengthtothe
requiredvalue(between0.25and2.50).
4.PresstheTimerandResetbuttonssimultaneouslytocommence
thespeedruncalibration
Thecalibrationstatuspageisdisplayed.Thetextatthetopof
thepagealternatesbetweenSTART1andthecalibrationfactor
currentlyapplied.
D12 4 5 5-1
Re s e tTim e r
+
5.Starttheoutwardlegofthecalibrationrunandasyoupassthe
startpoint,presstheTripbutton,sothepageshowsOUTWARD
atthetop.Asthecalibrationrunproceeds,thedisplayedvalue
willchange.
D12 4 5 6-1
Trip
34i50
Seitenansicht 33