Inverter/Chargers
Mastervolt Mass Combination Inverter/Chargers
ttery hrn slyn 1 ower swthn n the se of etene  los to e tle on or een
when limited shore power is available. Power can be drawn from a shore connection, generator or charged batteries.
Mastervolt’s three-step plus charging method guarantees more battery power and a longer life span. These units are
1/2 the weight and 1/2 the amp draw of traditional inverter/chargers..
MSV 37-01-2005 MSV 37-02-2005 MSV 37-01-4005 MSV 37-02-4005
DC input voltage (nominal) 12V 24V 12V 24V
DC input voltage range 10-15V 20-31V 10-15V 20-31V
Continuous power @ 25°C / 77°F 2000 VA / 16.7A 3750VA / 16.5A
Parallel use (to double the power) yes no
Parallel with shore/generator yes yes
Dimensions (H x W x D) 18.1" x 12.5" x 5.6" 18.7" x 12.5" x 10"
Weight 24.3 lbs 46.3 lbs
Max. charge rate (adjustable) 100A @ 14.25V DC 60A @ 28.5V DC 200A @ 14.25V 100A @ 28.5V
Primary AC consumption 1635 VA / 14.5A 1955 VA - 17A 3270 VA - 29A 5270 VA - 29A
Charge voltage @ 25°C / 77°F 14.25 / 13.25V 28.5 / 26.5V 14.25 / 13.25V 28.5 / 26.5V
Second charge output, 3stage 5A 2 x 5A
Temperature sensor battery 6 metre cable and telejack plug standard 20' Cable & Telejack
re newe for len efent ower
High surge power output when starting
wth oe tehnoloy  etreely lht weht  ot
Generator / shore support - Parallel to generator or shore to increase start-up power
with limited generator power
tt ower rte t e olte
3 stage + battery charging of up to 3 battery banks of lead acid, gel or AGM batteries
hrer hs the lty to ree  e ttery nles n lry ower sly
Built-in GND relay
Ground stud
Automatic transfer switch
Variable speed fans for cooling
eet   n  rereents
Includes battery temperature sensor and ICC Remote Panel
Standard panel comes with the Mass Combis (panel frame
exclusive). It indicates DC consumption, charge phase, failure
and AC availability and contains a ’charger only’ on/off switch.
Connection cable (6m) included
Newmar Inverter/Chargers
hese nerters ott re snsol  for efent oerton of ll lnes ls los wth senste
eletrons n roroessors sh s oters n el eent or ltons where rellty
and performance are paramount, and low noise operation has become a critical factor. All connectors and
mounts are heavy duty commercial grade.
Built-in high output charger for rapid battery bank replenishment - 1800-3000 watt models feature three
ste hrer wth ott rorle for elell ooe le or  ttery tye n 
hour capacity selector for proper charging in various applications
nternl hrer s tte y n tot trnsfer rely wheneer eternl  ower s lle
Large DC input terminal blocks and front panel GFCI protected outlet receptacles (AC may be hard-wired)
All important aspects of inverter and charger operation clearly displayed with front panel status indicators -
optional remote panel available (See below)
Short circuit, overload, over-temp, ground fault and output circuit breaker protection
Thermally controlled cooling fan prolongs life of components
Automatic low voltage shutdown circuit prevents damage to batteries
Powder coated aluminum and con-formal coated internal circuitry
UL listed with full two year warranty
Part #
Battery
Voltage
Inverter Output
Surge/Continuous
Charger Output
Max Amps @V
Charger
Input Max
Amps
Case
Type
Weight
lbs
NEW 12-1800IC
12 4000/1800 85A@12V 15 I-2 54
NEW 12-3000IC
12 6500/3000 105A@12V 20 I-3 75
NEW 24-2200IC
24 6500/2200 40A@24V 15 I-2 57
NEW 24-4800IC
24 14,000/4800 115A@24V 40 I-3 95
Ref Height x Width x Depth (mm)
I-2 7.5”(19.1) x 16.0”(40.6) x 15.5”(39.4)
I-3 10”(25.4) x 17”(43.2) x 16”(40.6)
Remote Panel
Remote control and
indicator panel,
duplicates all status
indicators found on unit front
panel and allows remote ON/
OFF capability. Provided with
25' of cable.
NEW ICR-2-25