Chapter 1: Diagnostics & Software Upgrades 3
COMMERCIAL IN CONFIDENCE
For information only
For information only
COMMERCIAL IN CONFIDENCE
Diagnostic charts
If it appears that an ST70 product is not operating satisfactorily, use the following charts to determine how to
resolve the problem:
If there is nothing on the screen - refer to Chart 1.
If data is missing from the screen - refer to Chart 2.
Is power on at any other
product in the system?*
Is the display lit?
Is the display lit?
Are the instrument
buttons back-lit?
Are the instrument
buttons back-lit?
Switch on power to the
system
Is problem still
present?
Return to
normal
operation
Return to
normal
operation
Return to
normal
operation
At faulty instrument, carry
out switch-on procedure
Check display brightness
setting and adjust as
necessary (see Operating
Guide)
Replace
connecting
cable
Return to
normal
operation
Ensure all system
connections are made
satisfactorily
Nothing on
screen
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
YES
NO
Is problem still
present?
ST70 troubleshooting
Chart 1
D10478-1
Swap connecting cable to other
connector on rear of product
* The system to which the instrument is connected
(either SeaTalk, SeaTalk or SeaTalk )
2
ng
YES
NO
Is problem still
present?
Repair internal
connections