Raymarine ST60 Installationshandbuch

Stöbern Sie online oder laden Sie Installationshandbuch nach Nein Raymarine ST60 herunter. Raymarine ST60 Installation manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 50
  • Inhaltsverzeichnis
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 0
ST60 Wind &
Close Hauled
Wind
Instruments
Owner’s
Handbook
Document number: 81105-3
Date: 1st April 1999
105_3cov.p65 06/04/01, 10:461
Seitenansicht 0
1 2 3 4 5 6 ... 49 50

Inhaltsverzeichnis

Seite 1 - Date: 1st April 1999

ST60 Wind &Close HauledWindInstrumentsOwner’sHandbookDocument number: 81105-3Date: 1st April 1999105_3cov.p65 06/04/01, 10:461

Seite 2 - 105_3cov.p65 06/04/01, 10:462

viii ST60 Wind and Close Hauled Wind Instrument Owner’s HandbookParts suppliedUnpack your ST60 instrument and check that the following items arepresen

Seite 3 - Contents

Introduction ixWorldwideDistributorsD4442-2ST60 WindInstrumentOwner'sHandbook1a 1b48932325b6These items are not with ST60 Close Hauled Wind711105

Seite 4 - 105_3int.p65 06/04/01, 10:462

x ST60 Wind and Close Hauled Wind Instrument Owner’s Handbook105_3int.p65 06/04/01, 10:4710

Seite 5 - Introduction iii

Chapter 1: Operation1Chapter 1: Operation1.1 Getting startedThis handbook describes how to operate, maintain and install theRaymarine ST60 Wind instru

Seite 6 - 105_3int.p65 06/04/01, 10:464

2ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookDigital displayThe digital display shows the following wind and speed information:• True/

Seite 7 - Introduction

Chapter 1: Operation3The flow charts show the sequence of key presses and displays for thevarious operating tasks. All key presses called for in the f

Seite 8 - Data inputs

4ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookTrue/ApparentPress the true/app. key to toggle between true and apparentinstrument readin

Seite 9 - Mounting options

Chapter 1: Operation5Setting alarm conditionsThe alarm threshold screens are accessed with the disp key (see theUsing the disp key flow chart), and en

Seite 10 - Parts supplied

6ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook1.3 Display illuminationWhen the instrument is first powered up, the display illumination

Seite 11 - Introduction ix

Chapter 2: Maintenance and Fault Finding 7Chapter 2: Maintenance and Fault Finding2.1 MaintenanceServicing and safety• Raymarine equipment should be s

Seite 12

© Copyright Raymarine Limited 2001105_3cov.p65 06/04/01, 10:462

Seite 13 - Chapter 1: Operation

8 ST60 Wind and ST60 Close Hauled Wind Instrument Owner’s Handbook2.2 Fault findingPrPrPrPrPreliminary preliminary preliminary preliminary preliminary

Seite 14 - 1.2 Normal operation

Chapter 3: Installation9Chapter 3: InstallationThis chapter describes how to install the ST60 Wind and ST60 CloseHauled Wind instruments, and associat

Seite 15 - Using the disp key

10ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookInstrumentInstrumentInstrumentInstrumentInstrument110mm (4.33in) 24mm(0.95in) 15mm(0.6in

Seite 16 - True/Apparent

Chapter 3: Installation11EMC guidelinesAll Raymarine equipment and accessories are designed to the bestindustry standards for use in the leisure marin

Seite 17 - Setting alarm conditions

12ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookConnections to other equipmentIf your Raymarine equipment is going to be connected to ot

Seite 18 - 1.4 Remote control

Chapter 3: Installation13The ST60 instruments can also be mounted behind a panel with justthe instrument dial and keys visible.Surface mountingTo surf

Seite 19 - 2.1 Maintenance

14ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookFlush mountingThe Flush Mounting Kit uses a low-profile bezel to reduce the fittedprofil

Seite 20 - 2.2 Fault finding

Chapter 3: Installation15D4356-2789Fitting the low profile bezelFlush mounting procedureFlush mount your instrument ( see the Flush mounting illustrat

Seite 21 - Chapter 3: Installation

16ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook D4307-3Flush mounting11345566. Screw the two fixing studs (1) into

Seite 22 - CAUTION:

Chapter 3: Installation17Note: An ST60 Close Hauled Wind instrument can only be used as arepeater instrument so a directly-connected transducer is not

Seite 23 - EMC guidelines

Introduction iContentsIntroduction... vEMC conformance ...

Seite 24 - 3.2 Procedure

18ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookRotavectaThe Rotavecta can be clamped to a 23 mm or a 25 mm rail by means ofan integral

Seite 25 - Surface mounting

Chapter 3: Installation19• If the cable has to be fed through the deck, always use a proprietarydeck gland.• Where cables are fed through holes, alway

Seite 26 - Flush mounting

20ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook4. Connect each wire at one end of the remaining cable to the same-coloured wire inside

Seite 27

Chapter 3: Installation21A range of Raymarine SeaTalk extension cables is available to connectseparated instruments. These cables are supplied with a

Seite 28 - Fitting transducers

22ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookPower supply connectionsSeaTalk systemsCAUTIONWhen instruments are connected to SeaTalk,

Seite 29 - Typical windvane installation

Chapter 3: Installation23 To fit a power cable:1. Run the cable from the instrument to a suitable 12 V dc powersource.Power connections for stand-alon

Seite 30 - Running transducer cable

24ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook105_3c03.p65 06/04/01, 10:4724

Seite 31 - Preparing wire for connection

Chapter 4: Calibration 25Chapter 4: Calibration4.1 IntroductionThe ST60 Wind instruments are set up with factory-programmeddefault settings, so in ord

Seite 32 - Connecting the instruments

26ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook3. Hold down the disp and true/app keys for approximately2 seconds to enter User calibra

Seite 33 - Signal connections

Chapter 4: Calibration 274.3 Intermediate calibrationThe intermediate calibration screens enable you to check:• The instrument software version number

Seite 34 - Power supply connections

ii ST60 Wind and Close Hauled Wind Instrument Owner’s HandbookChapter 2: Maintenance and Fault Finding ... 72.1 Maintenance ...

Seite 35

28ST60 Wind and Close Hauled Wind Instruments Owner’s HandbookDealer calibration also gives access to the Factory defaults screen. Thisenables you to

Seite 36

Chapter 4: Calibration 29TRUEAPPHold down and for approximately 12 secondsdisptrueappDealer calibration - sheet 1Entry screenTRUEAPPTRUEAPPTRUEAPPvmgt

Seite 37 - Chapter 4: Calibration

30ST60 Wind and Close Hauled Wind Instruments Owner’s Handbookanddisptrueappto either apply factory defaultsor retain current settings(F1 = factory de

Seite 38 - Leaving User calibration

Chapter 4: Calibration 31Boat show mode (bSO)CAUTION:Do NOT enable this mode. It must only be used for demonstrationpurposes.Ensure that the Boatshow

Seite 39 - 4.4 Dealer calibration

32ST60 Wind and Close Hauled Wind Instruments Owner’s Handbook105_3c04.p65 06/04/01, 10:4732

Seite 40 - Wind speed

D4436-1Machine hole90mm (3.54in)diameterDrill 5mm (3/16in) diameterDrill 5mm (3/16in) diameterShaded areas to be removedTOPST60 Surface Mount Template

Seite 41 - Chapter 4: Calibration 29

105_3tem.p65 06/04/01, 10:4734

Seite 42 - Dealer calibration - sheet 2

Shaded area to be removedTOP109 mmST60 Flush Mount Template114 mm4 holes6 mm diameterD4437-1105_3tem.p65 06/04/01, 10:4735

Seite 43 - Leaving Dealer calibration

105_3tem.p65 06/04/01, 10:4736

Seite 44

Document number: 84064-8April 2001Limited Warranty CertificateRaymarine warrants each new Light Marine/Dealer Distributor Product to be of good materi

Seite 45 - ST60 Surface Mount Template

Introduction iiiRunning transducer cable ... 18General ... 18

Seite 46

Factory Service CentersUnited States of America UK, Europe, Middle East, Far EastRaymarine Inc22 Cotton Road, Unit DNashua, NH 03063-4219

Seite 47 - ST60 Flush Mount Template

iv ST60 Wind and Close Hauled Wind Instrument Owner’s Handbook105_3int.p65 06/04/01, 10:464

Seite 48

Introduction vIntroductionThank you for purchasing a Raymarine product. We are sure yourST60 instrument will give you many years of trouble-free opera

Seite 49 - Limited Warranty Certificate

vi ST60 Wind and Close Hauled Wind Instrument Owner’s HandbookEMC conformanceAll Raymarine equipment and accessories are designed to the bestindustry

Seite 50 - Factory Service Centers

Introduction viiStand alone operationIn Stand alone operation, the ST60 Wind instrument is connected onlyto the relevant transducer and does not displ